Post Offer Free
Shanghai Jiayu Environmental Technology Co., LTD  

Gold Index: 6123

You are here: home  > IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis 

Place of Origin: Zhejiang, China (Mainland) 
inquire
Add to My Favorites
HiSupplier Escrow
Share |

Product Detail

Model No.: CNJY-S

 
IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis
 
 </p

 

IS9001 Approval Sodium Hypochlorite Generator / Sodium Hypochlorite Electrolysis

 

 

Technical parameters:

 

Type

Av.CL2 Capacity
 (g/h)

Flow Rate
 (L/h)

Salt Consumption
 (kg/d)

Water
Consumption
(m3/d)

Rated power
 (kw )

Unite size
 (L×W×H)
(mm)

CNJY-S-100

100

13

8.4

0.31

0.6

1200×800×1400

CNJY-S-200

200

25

16.8

0.6

1.2

1200×800×1400

CNJY-S-300

300

38

25.2

0.91

1.8

1200×800×1400

CNJY-S-400

400

50

33.6

1.2

2.4

1200×800×1400

CNJY-S-500

500

63

42

1.51

3

1200×800×1400

 


Note:System requirements with salt and water
 

Salt requirements:

 

Name

Request content( %)

(NaCl)

>99.3 %

(Fe)

<0.002%

(Ca Mg)

<0.023%

(Mn)

<0.00003%

(Pb)

<0.0007%

(Cu)

<0.0003%

(F)

<0.01%

 

Water requirements:
1)Operating water temperature:
The temperature between (18C-23C)is best. If do not use temperature regulation, please allow the temperature between (10C-27C),or a heating exchanger or chiller equipment to be used for adjust the water temperature.
2)Operating water pressure:
Minimum 0.2 MPa, Maximum 0.35 Mpa, if not in this scope, need to increase a he pressure or vacuum equipment
3)water quality requirements:
pH 6.5 to 8.5
hardness[in calcium carbonate] < 5 ppm (soft water equipment outlet)
COD(Mn) < 1.5 ppm
Fe < 0.2  ppm
Mn < 0.01 ppm
Ni < 5 ppm
F <2 ppm
Cu < 5 ppb

 

 

Product introduction:
 
Generation principle:
 
    The revolutionary CNJY-S series sodium hypochlorite generator is a newly and for on-site product of NaClO equipment and use for all kinds of needed NaClO disinfected. Its working principle is :the sodium chloride solution under the certain voltage effect of the cell, a series of electrochemical reaction within the cell and the resulting solution is the NaClO solution. The main process can be simplified as follows:
 

The electrode reaction:
anode:2Cl--2e→Cl2
cathode:2H++2e→H2
solution:2NaOH+Cl2→NaCl+NaClO+H2O
 
Work flow chart:
 
 

Product components system
 
A,inlet water distribution system
Main components: water pressure gauge, water softener, soft water pump, water meter, salt tank, salt water pump and related piping and valves.
 

B,The power control system:
Including control cabinet, rectifier and cable connection.
 


C,Storage and dosing system
Including electrolytic cell, NaClO tank, dosing pump, piping and valves.
 

 
 
Advantage of on-site sodium hypochlorite generator
 
SAFETY:
Material safety: Salt, Water and Electricity as raw materials, no need for transportation of dangerous chemicals;
Process safety: No risk of chlorine leakage and reactor explosion, safety for operator;
Product safety: Product-0.8% NaCIO solution, has the advantage of stable and safety, cost effective in operation and no attenuation in storage.
ENERGY-SAVING:
Make use of electricity in the off-peak period to generate the NaCIO solution.
ENVIRONMENTAL PROTECTION:
Avoid of usage, transportation of dangerous chemical material.
High current efficiency ,few by-product, safe H2 ventilation.
ECONOMY:
JIAYU equipment can largely reduce the operation cost compared to the bulk hypochlorite

 
TAG:

Sodium hypochlorite generator, On-site sodium hypochlorite

 

 

DETAILS:

 


 
 

bigPhoto
 Mr. Miss. Sherry

Tel: 86-21-61280157
Contact to this supplier

Related Search

Find more related products in following catalogs on Hisupplier.com

Company Info

Shanghai Jiayu Environmental Technology Co., LTD [China (Mainland)]


Business Type:Manufacturer
City: Shanghai
Province/State: Shanghai
Country/Region: China (Mainland)

You May Like:

Product (113)